Drying plant layout

Drying Plant Layout and Utility Requirements | Building, Power, Steam and Water

Most drying projects are sized by budget first and building second – then the building bites back. Three numbers decide whether a line fits: straight-line length, power supply and heat source capacity. This page gives the working dimensions, utility loads and layout options for drying plants from a single heat pump room to a 90-metre continuous line, so you can check your site before you commit.

8-90 m line length4-6 m clear height18-540 kW power classes1-12 x 40HQ containersStraight, L or U layout
Continuous mesh belt drying machine installed in a customer factory
Quick Answer

A drying plant needs three numbers checked before anything is ordered: straight-line length for the equipment chain, installed power (or steam/gas) for the heat load, and floor loading with drainage in the wet end. A room-based plant fits an 8×6 m shed; a continuous line needs 30-90 m of straight run.

Power classes: batch room plants run 18-80 kW, mid-size mixed lines 80-200 kW, and continuous belt lines 110-540 kW depending on the heat source. Biomass or gas heat replaces most of the electrical load where fuel is cheap.

Container planning: a room plant ships in 1-2 x 40HQ, a batch system in 3-5, and a full continuous plant in 6-12 x 40HQ. Equipment is typically only 35-55% of a landed project – the civil works, power feed and installation around it are planned on this page’s numbers.

8-90 mline length by capacity
4-6 mclear height range
18-540 kWinstalled power classes
1-12 x 40HQcontainers per project
3-5 tfloor point load in equipment zones
Footprint

Building Dimensions By Plant Type

Item Room plant (batch) Mixed batch system Continuous line Data basis
Straight-line length 8-12 m 20-35 m 40-90 m B – industry
Width 6-8 m 8-12 m 10-16 m B – industry
Clear height 3.5-4.5 m 4.5-5 m 5-6 m B
Door size (widest) 1.5×2 m 2×2.2 m 3×3 m for module entry B
Floor washable, drained food-grade, 3 t point load food-grade, 5 t point load, drains along the line B – industry
Layout options single row straight or L straight, L or U around packing B

Dimensions are for the equipment chain itself – add 2-3 m of working aisle on each side and space for trolleys, bins and pallet staging.

Utilities

Power, Heat, Water and Air By Tier

Utility Room plant Mixed batch system Continuous line Data basis
Electricity (installed) 18-80 kW 80-200 kW 110-540 kW B – industry
Steam (where used) 0.3-1 t/h 1-2.5 t/h 2.5-6.5 t/h C – estimate
Biomass/gas alternative optional 150-350 kg/h wood equiv. 350-1000 kg/h wood equiv. C – estimate
Water (washing) 2-5 m³/day 8-20 m³/day 20-50 m³/day C – estimate
Compressed air not required 0.2-0.4 m³/min 0.4-0.8 m³/min C – estimate
Drainage floor drain at washer channel along wet end channel + settlement pit before discharge B – industry

Where grid power is weak, biomass or gas carries the drying heat and electricity drops to fans and conveyors – typically 30-40% of the figures above. Figures marked C are typical, to be confirmed by test.

Solution

Installed Plants, Every Machine Ours

Industrial continuous mesh belt vegetable drying machine
Continuous belt dryer installed on a prepared floor slab
Air-source heat pump food drying room with PLC control installed outdoors at a fruit farm
Heat pump rooms set outside the building, ducted through the wall
Double-chamber hot air circulation tray oven installed in a customer workshop, trolleys inside
Batch tray ovens commissioned inside a customer workshop
Quick Quote

Tell Us Your Material And Capacity – We Size The Line

  • Material, variety and initial moisture
  • Fresh input per day or per hour
  • Target final moisture and finished grade
  • Available heat source and factory dimensions

Prefer email? Write to info@tondemachine.com or WhatsApp +86 185 0387 4173. Our engineers reply within one working day.

    Scope

    One Supplier Draws The Layout With The Quotation

    A layout drawing is not a favour after the sale – it is how a quotation becomes honest. We draw the chain on your floor plan before you commit: equipment positions, aisle widths, power drops, drain runs, door swings and where the trolleys and bins stage between batches.

    Because every machine in the chain – washers, cutters, belt dryers, rooms, mills, packers – is built in our own factory, the layout is drawn from equipment dimensions we manufacture, not from a catalogue we hope will fit.

    That is also why our landed-cost quotes carry the full utility and civil scope on one page: the same team that sizes the dryer sizes the power feed, the steam line and the drainage it needs.

    Layout Options

    Straight, L or U – Which Fits Your Building

    Option Best for Trade-off
    Straight Continuous lines, long narrow sheds Simple flow, fewest conveyors; needs the full length in one hall
    L-shape Batch rooms + belt mix, corner buildings Turns the flow 90° at the dryer discharge; adds one transfer conveyor
    U-shape Packing-heavy plants, square buildings Intake and dispatch share one wall; needs a turnback aisle and stricter zoning

    The turnback in a U-shape is also a hygiene boundary: wet end inside the U, dry end and packing outside it.

    Get a Layout

    Send Your Material Data – Get a Line Layout & Price

    • Daily or hourly fresh input and target final moisture
    • Available heat source: electric, steam, gas, biomass or diesel
    • Factory length, width and clear height
    • Target market grade and packing format

    Prefer email? Write to info@tondemachine.com or WhatsApp +86 185 0387 4173. Our engineers reply within one working day.

      Line Photos

      Installations and Assembly

      Multi-layer belt drying machine installed in factory
      Belt dryer installed and aligned in the customer building
      Hot air circulation tray oven units with protective film in final assembly at our workshop
      Tray oven units lined up in final assembly before dispatch
      Continuous mesh belt drying machine assembled in the workshop
      Continuous dryer assembled in the workshop for factory testing
      Site Checklist

      What To Confirm Before Ordering

      Check What to measure Why it bites later
      Power feed Transformer capacity vs installed load, +30% margin A line that outruns its transformer throttles every zone
      Floor slab Thickness, level (±5 mm/10 m), point load Belt lines are aligned on the slab – poor levels show as tracking faults
      Drainage Slope to drain, settlement pit capacity Wash water carries soil and sugar; no drainage means no hygiene
      Steam or fuel Boiler capacity or biomass storage space Fuel storage is a building decision, not an equipment one
      Access Container truck route, unloading space, door sizes Modules that cannot reach the hall get unloaded by crane, at a price
      Expansion Space for one more room or one more belt section Most plants grow within two years – leave the lane empty
      Data Basis

      How To Read The Numbers On This Page

      About the numbers on this page. Capacity, temperature and moisture figures are industry-typical values for this material. Energy consumption, utility requirements, floor space and payback are engineering estimates and are marked typical, to be confirmed by test. We confirm every figure against a drying test with your own material before quotation. Price ranges are indicative ex-works figures and exclude freight, customs clearance, civil works, utilities, installation and commissioning – equipment typically accounts for 35–55% of a landed project budget.

      FAQ

      Frequently Asked Questions

      What is the minimum building for a usable plant?

      A single heat pump room with washing and packing fits an 8×6 m shed with 3.5 m clear height and an 18-25 kW feed. It processes 1-2 t/day of fresh material and can grow with more rooms.

      Can I run a line on a generator or weak grid?

      Yes, with planning. Biomass or gas carries the heat and electricity drops to fans and conveyors – typically 30-40% of the installed figures above. We size the generator against the actual motor start-up sequence, not just the running load.

      How much steam does a drying plant need?

      Only lines with blanching or steam heat need a boiler: roughly 0.3-1 t/h for a room plant up to 2.5-6.5 t/h for large continuous lines. Heat pump and direct-fired lines need no steam at all – it is a heat-source choice, not a requirement.

      Does the floor really need special construction?

      The wet end needs washable, drained, food-grade floor; equipment zones need 3-5 t point load capacity. A belt line aligned on a soft or unlevel slab will fight tracking problems for its whole life.

      How are the machines shipped?

      Knock-down in 40HQ containers: a room plant in 1-2, a batch system in 3-5, a full continuous line in 6-12. We provide the container plan with the layout so the building access is planned around it.

      Do you provide the layout drawing before I pay?

      Yes – the layout drawing and utility specification are part of the quotation, drawn on your floor plan. We will not quote a line we have not laid out.

      Request a Quotation

      Request Your Turnkey Quotation

      • Factory-direct price, no middleman
      • Process design, layout drawing and utility specification
      • Drying test with your own material before quotation
      • Worldwide shipping, installation and remote commissioning support

      Prefer email? Write to info@tondemachine.com or WhatsApp +86 185 0387 4173. Our engineers reply within one working day.